Home › Nefit error codes › Boiler › Error code 2F 260

Nefit Boiler Error Code 2F 260

DIY checks firstReviewed November 2026Checked against manufacturer documentation
What this code means
2F 260: The flow temperature sensor measures no temperature rise after a burner start

Code 2F 260 means the burner does start, but the flow sensor sees no rise in temperature. Usually the water is not moving: there is air in the boiler or the pump is not running. Topping up and bleeding thoroughly is the first step. If the code keeps returning, an installer must measure the pump and the sensor. Code 2F 345 has the same meaning.

Also shown as: 2F

Applies to: Nefit ProLine and TrendLine condensing boilers

Fix level
DIY checks first
Start with the checks on this page. Testing or replacing a part is usually a technician job.
Time to run the checks
About 20–40 minutes
For the 4 checks on this page — not a full repair.
You may need
No special tools
The checks below use basic household items only.
Parts that may be involved
Circulation pump, Flow temperature sensor
Parts are model-specific; see the note below before ordering.

Common causes

  1. Air in the boiler or the system, so there is no flow
  2. Circulation pump not running, so the heat stays at the burner
  3. Water pressure too low

What to check, in order

Safety first. A boiler works with gas, electricity and hot water under pressure. Never open the casing or touch anything inside it. In the Netherlands, work on a gas boiler may only be done by a certified company (CO-vrij). The checks on this page stay on the outside: water pressure, thermostat, radiators and the reset button. If you smell gas, leave the building and call the national gas emergency number 0800-9009 (Netherlands).
  1. Check the water pressure and top up to 1.5 to 2 bar if needed.
  2. Bleed the radiators and the boiler and open all radiator valves.
  3. Press the reset button once and see whether the boiler now heats up.
  4. If the code returns, call a CO-certified installer; the pump and sensor need to be measured.

Clear the code and test

  1. Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back.
  2. Make sure the boiler has power and the gas tap at the boiler is open.
  3. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
  4. Press the reset button once and watch a full cycle: the boiler should start, heat the radiators or the tap water, and keep running without the code coming back.

When to call a professional

Most cases are solved by the checks above. Book a technician if any of these apply:

  • The code comes back after you have run the checks and a test cycle.
  • You smell burning, see sparks or scorch marks, or the breaker trips.
  • Water is leaking and you cannot stop it.
  • The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.

When you call, give the brand, the code 2F 260, your model number (on a label on the type plate, usually at the bottom or on the side of the boiler) and the checks you already ran. It shortens the visit.

Parts that may be involved

Circulation pumpFlow temperature sensor

Parts are model-specific. Find your model number first — usually on a label on the type plate, usually at the bottom or on the side of the boiler — and match the part to that number before ordering.

Questions people ask about 2F 260

What does 2F 260 mean on a Nefit boiler?

2F 260 means: The flow temperature sensor measures no temperature rise after a burner start. Code 2F 260 means the burner does start, but the flow sensor sees no rise in temperature. Usually the water is not moving: there is air in the boiler or the pump is not running. Topping up and bleeding thoroughly is the first step. If the code keeps returning, an installer must measure the pump and the sensor. Code 2F 345 has the same meaning.

Can I fix Nefit 2F 260 myself?

Start yourself: the checks on this page cover the causes you can reach without opening the machine up. If they point to a faulty part, testing or replacing it is usually a technician job.

How do I clear Nefit 2F 260?

Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back. Make sure the boiler has power and the gas tap at the boiler is open. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.

Sources checked

The meaning and checks for this code were checked against the sources above in November 2026. Codes vary by model and region; if your manual lists a different meaning for your exact model, follow the manual.

Other Nefit boiler codes

See all Nefit boiler error codes